Implementation of EnviroConnect - for Forbes Marshall Pvt. Ltd.


Background

Forbes Marshall Codel is a leading manufacturer, of various pollution measuring sensors and devices. It has large no. of installations across India in various types of industries like cement power textile mills etc. As per Central Pollution Control Board (CPCB) guidelines Forbes Marshall Codel is required to set up a dedicated server in CPCB premises and later in each of the SPCB premises where the data from various installations will be made available. AIPL’s solution, EnviroConnect offers an ideal platform for Forbes Marshall Codel to meet above requirements.


FM has installed a server at Central Pollution Control Board (CPCB) office at New Delhi. FM has selected EnviroConnect software for all their requirements like collecting real time data of all industries and display at the server, public portal so general public can view the data, reports, alarms etc.



Project Objectives

    1. To install and operate a central portal under control of CPCB which will be the aggregator for pollution data from all installations
    2. To upload data in real time from all installations.
    3. To store and archive all such data for analysis and reporting
    4. To generate relevant alarms/ alerts and warnings based on real time data
    5. To provide additional functionality for authorized users for data management and analysis as well as for generating reports
    6. Report generation and distribution as per configuration
    7. Availability of real time data and other information to citizens through a public portal


      Solution

      EnviroConnect is a ready to deploy solution with full and advanced functionality, dash board based viewing, evolved alarms and alerts management and powerful reporting. The solution is proven in the field and is currently deployed in various industries. The solution is designed based on global standards of ambient monitoring requirements of various pollution boards and further tuned to the requirements as laid down by CPCB for Indian standards.


      Selection of System by Forbes Marshall Codel

      Based on the project objectives and technical requirements put up by Central Pollution Control Board (CPCB) office, Forbes Marshall Pvt. Ltd. evaluated and selected EnviroConnect as the most appropriate solution for the project. Main reasons for this selection were:


      • EnviroConnect was a ready solution with all required functionality

      • EnviroConnect has strong analytical and reporting features as required by CPCB

      • EnviroConnect has strong server component to handle large data load


      Solution sample screen shots and report





      Technical details of project and installation
      Hardware installed and connected:

      • Insitu Multi Gas Analyser - FM CODEL GCEM4000
      Analyzers capable of measuring gases as follows
      CO
      CO2
      NO
      NO2
      SO2
      HCL
      H2O
      • Opacity / Dust Monitor - FM CODEL DCEM2100

      Measures opacity and dust

      • Airpointer (File based communication)

      Measures ambient gases


      Device drivers implemented in the project

          
       Equipment Driver
       1
       Insitu Multi Gas Analyser - FM CODEL GCEM4000 Serial communication using ModbusRTU  driver
       2
       Met Opacity / Dust Monitor - FM CODEL  DCEM2100 Serial communication using Modbus RTU  driver
       3
       Airpointer File based communication


      Current status of the project

      AIPL has successfully completed 200 plus installations. The system is in operation successfully. We are in the process of rolling out huge number of installation in next two years. FM officials are happy with system performance and features as well as support. We have also demonstrated this system at CPCB recently and all the officials were satisfied with the performance. They confirmed that PlantConnect is meeting the system requirements laid down by them.

       

      The system can be accessed at: http://203.145.138.170:8080/plantconnect/aqms                                                                >>View PDF